| Sign In | Join Free | My webtextiles.com |
|
Brand Name : Fenigal
Model Number : Fenigal
Certification : CE
Place of Origin : china
MOQ : 1 pc
Payment Terms : T/T, Western Union
Supply Ability : 60000 Unit/Units per Month
Delivery Time : 5-8 working days
Packaging Details : standard export packing
Rated insulation voltage (V) : 440
Rated impulse withstand voltage (kV) : 6
Rated operation voltage ( ) : 50HZ
Number of poles : 3/4
Electrical endurance (*) : AC50Hz 440V-In
Operation mode : Intermittent operation
Class PC Automatic Transfer Switch with Overcurrent Release and Rated Current 100-630A

| WATSN-100 | WATSN-160 | WATSN-250 | WATSN-400 | WATSN-630 | ||||
| Number of poles | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | |||
| Controller | ||||||||
| Type A | ■ | ■ | ■ | |||||
| Type B | ■ | ■ | ■ | ■ | ■ | |||
| Type D | ■ | ■ | ■ | ■ | ■ | |||
| Actuation component | NSX-NA | |||||||
| Conventional thermal current (A) | Ie | 60℃ | 100 | 160 | 250 | 400 | 630 | |
| Ui | 690 | 690 | 690 | 690 | 690 | |||
| Rated impulse withstand voltage (kV) | Uimp | 8 | 8 | 8 | 8 | 8 | ||
| Rated operation voltage (V) | Ue | AC50Hz | 400 | 400 | 400 | 400 | 400 | |
| Making capacity | Icm (kA peak) | 17 | 17 | 17 | 52.5 | 52.5 | ||
| Rated short-time withstand current | Icw (kA effective) | 30mS | 10 | 10 | 10 | - | - | |
| 60ms | - | - | - | 25 | 25 | |||
| With elf-protection function | (*) | Yes | Yes | Yes | Yes | Yes | ||
| Isolation function | ■ | ■ | ■ | ■ | ■ | |||
| Pollution degree | Ⅲ | Ⅲ | Ⅲ | Ⅲ | Ⅲ | |||
| Real closing indication | Yes | Yes | Yes | Yes | Yes | |||
| Mechanical endurance | (**) | 12000 | 12000 | 12000 | 12000 | 12000 | ||
| Electrical endurance | (**) | AC50Hz | 440V-In | 6000 | 6000 | 6000 | 6000 | 6000 |
| Operation mode | Intermittent operation | ■ | ■ | ■ | ■ | ■ | ||
| Control characteristics | ||||||||
| Minimum contact transfer time | S | 1.5 | 1.5 | 1.5 | 2 | 2 | ||
| lnstallation and connection accessories | ||||||||
| Fixation/panel front connection | ■ | ■ | ■ | ■ | ■ | |||
| Circuit breaker phase partition | (***) | Optional | Optional | Optional | Optional | Optional | ||
| Position feedback signal | Optional | Optional | Optional | Optional | Optional | |||
| Fire protection linkage function | Optional | Optional | Optional | Optional | Optional | |||
Notes: (*) Trip under surge of high short-circuit current (**) Maximum expected value with proper maintenance (***) Safety accessories, non-standard configuration
|
|
Class PC Automatic Transfer Switch with Overcurrent Release and Rated Current 100-630A Images |